Home Page  
Company Profile  
Showroom  
Wires/Cables & Accessories
SHUBHAM ENTERPRISES
PVC Insulated Submersible Winding Wires
To inquire, Select Product/s & Click on

Product Code : 08

[Select]
Product Specification
Single Core PVC FRLS Insulated Copper Conductor (Unsheathed)

House Wires in Voltage Grade Upto & Including 1100 Volts As Per IS 694 - 1990

Nominal Cross
Section Area of
Conductor
Sq. mm.
Configuration
Dia. of
Wires
Number / mm
Thickness
of
Insulation
mm
Max.
Overall
Diameter
Current Carrying
Capacity in Conduit
/Trunking (Amps.)
Resistance
(Max.)
at 20oC
Ohm / Km
PVC
HR PVC
FRLS
0.75
10/0.30
0.60
2.8
7
8
7
26.00
1.00
14/0.30
0.70
3.2
11
13
11
18.10
1.50
22/0.30
0.70
3.4
13
16
13
12.10
2.50
36/0.30
0.80
4.2
18
20
18
7.41
4.00
56/0.30
0.80
4.8
24
26
24
4.95
6.00
84/0.30
0.80
5.6
31
36
31
3.30

Comparative Properties of TECHMAX Wires

Features
Heat
Resistance
HR PVC
Fire
Resistance
FR PVC
Fire Retardant
Low Smoke
FRLS
Insulation Material
PVC
Sp. PVC
Spl. PVC
Insulation Property
Good
Good
Good
Temperature Rating
85oC
70oC
70oC
Thermal Stability
Very Good
Good
Good
Rame Retardancy
Good
Very Good
Very Good
Safety During burning
Average
Good
Good
Requirement of oxygen
to catch fire (% in Air)
>21
>30
>30
Temperature required
to catch fire (with 12% oxygen)
Room Temp.
>250oC
>250oC
Visibility during Cable
burning (%)
<20
<35
<40
Release of Halogen Gas
During buming (% by weight)
<20
<20
<20
Abrasion Resistance
During Installation
Good
Good
Good
  • Virgin electrical "A" Grade Copper rods are used in the manufacturing of the wires. These offer excellent resistance characteristics.
  • Bunched copper strands endure batter PVC retention properties.
  • The PVC compound used in the manufacturing process has an operating temperature of 85oC - most other wires have an operating temperature of 70oC.
  • The PVC compound had good abrasion resistance. This prevents damage to the insulation during wiring especially when the wires passed through conduits.
  • All coils are manufactured using automatic coiling machine online with extruders. This endures accurate diameter control and high voltage testing.
Other Products
Submersible Winding Wire
Submersible Winding Wire
Winding Wires For Submersible Pumps
Winding Wires For Submersible Pumps
Wires/Cables & Accessories
Wires/Cables & Accessories
 
<< Back
CONTACT DETAILS
1546, Bhagirath Palace, Chandni Chowk, Delhi - 110006, India
Phone:91-11-23873568/23862653
Fax:91-11-65380162/23862662
Send Mail  
Key Personnel
Mr. Anupam Gupta
Mobile:+919810017482
  
Copyright © 2006 tradeindia.com. All Rights Reserved. Designed & Developed by